0
Explosion Proof Mining Ventilation Fan

Explosion Proof Mining Ventilation Fan

Explosion Proof Mining Ventilation Fan
FBD series explosion proof ventilation fan (hereinafter referred to as fan) has the characteristics of reasonable structure, complete specifications, high efficiency, obvious energy saving effect, low noise, long air supply distance, etc.
Quantity
Contact Now
add to cart

Product Specification

FBD series explosion proof ventilation fan (hereinafter referred to as fan) has the characteristics of reasonable structure, complete specifications, high efficiency, obvious energy saving effect, low noise, long air supply distance, etc.

According to different requirements of ventilation resistance, the whole machine can be used or used in different levels, so as to reduce the ventilation time and save energy. The length of the tunnel is less than 2000m, so it can not move the ventilator to supply air normally, which reduces the labor intensity of the workers and saves the ventilation time. It is an ideal equipment for local ventilation in the coal mine. At the same time, it can also be used in metallurgy, nonferrous metals, gold, chemical industry, shipbuilding, ceramics and other high-pressure ventilation occasions.

The structure of the ventilator is characterized by explosion proof ventilation fan, contra rotating, silencing and axial flow. It is mainly used in the coal mine with the risk of methane gas explosion, and can be used for the medium and long-distance ventilation of the coal mining face. At the same time, it is also suitable for local ventilation and tunnel ventilation in other mines.

Main purpose and scope of application

The normal working conditions of the fan are:

1) It is mainly used in the coal mine with the risk of methane gas explosion. It is installed in the air inlet tunnel and used together with the positive pressure air duct for the forced ventilation;

2) Medium temperature – 20 ℃ ~ + 40 ℃;

3) The altitude is less than 1000m;

4) The humidity is not more than 95% (at 25 ℃).

Standards For Fans

The fan shall comply with MT222<< Technical Conditions Of partial Fan for coal mine>> and Q /ZFJ002<< FBD series mining explosion proof ventilation fan press in counter rotating axial flow partial fan>>

Working principle of ventilator

Each stage of the fan is driven by a explosion proof ventilation fan motor with the same rated power. The impeller is directly installed on the shaft extension of the motor, and the rotation direction of the impeller between adjacent stages is opposite. After entering the first stage impeller to obtain energy, the gas is accelerated by the second stage impeller and then discharged by the third stage impeller or the fourth stage impeller. The rear stage impeller has the function of the stationary blade in the ordinary axial-flow fan. It can not only obtain the velocity component in the straight circumferential direction, but also increase the air flow energy, so as to achieve higher air pressure and efficiency than the ordinary axial-flow fan.

The mining explosion proof ventilation fan press in counter rotating axial flow local fan produced by our company adopts the newly developed patent technology <>, and also adopts the first domestic patent technology <>

The patented product <> is installed at the air outlet of the fan, to automatically realize the locking of the main and auxiliary fans. When the main fan is running, under the action of wind pressure, the automatic switching device of the main fan will automatically open and the automatic switching device of the auxiliary fan will automatically close.

Main performance characteristics

1. The fan is composed of two or more working motors, and the adjacent impellers rotate in relative direction. That is to say, the number of two stage blades is prime to each other. The energy of the air is obtained by the first stage impeller and is sent out after being pressurized by the second stage impeller. In addition to increasing the air flow energy, the second stage impeller also has the function of static guide vane in the ordinary axial flow fan. While obtaining the velocity component in the direction of straightening the circumference, the second stage impeller straightens the air flow impact, increases the air flow energy, reduces the wake vortex, and reduces the noise.

2. In the whole working condition of the fan performance curve, the performance of the fan is improved, the power of the two-stage impeller shaft is balanced, and the maximum power is equal. The key point is to solve the problem that the shaft power of the two-stage impeller in the original pair of cyclones is unbalanced. When the pipeline resistance increases, the increase of the second stage shaft power speed leads to the excessive shaft power of the impeller at the same level, which is easy to burn down the motor.

3. Under various working conditions, the wind pressure is relatively gentle, the surge phenomenon is small, the operation is also stable in the area of high wind pressure and small flow, the air supply distance is far in the underground, and the adaptability is strong to the complex roadway. Key solutions: low efficiency, high energy consumption and high noise of the original pair of cyclones.

4. The new type of explosion proof ventilation fan (automatic switching explosion-proof counter rotating axial flow partial fan) highlights the advantages of high air pressure, long air supply distance and convenient switching. Key solutions: requirements of “four complete”, “three special”, “two locking” and “one switching” in partial fan management.

Technical performance Parameters of Two Stages Ventilation Fan

TypeRotaltion RatePowerRated Voltage

 (V)

Single MotorCapacity M3/MinTotal Pressure PaMaximum Total Pressure

%

A Sound Level (Db)Outer Dimention
R/MinKwRated Current

(A)

Φ×L(Mm)
№3.528402×2.2380/6604.8/2.8204~126760~11408622445×1135
№4.028302×1.1380/6602.5/1.492~47152~17078622575×1500
2×1.1(A)
28402×1.5380/6603.4/2.0111~56172~19338622
28402×2.2380/6604.8/2.8136~72251~21568622
28802×3380/6606.4/3.7115~86351~23008622
№5.028302×1.1(A)380/6602.5/1.492~47152~17078622700×1930
29002×4380/6608.1/4.7184~102231~22008622
29002×5.5380/660/114011.1/6.4/3.7200~100220~29508622
29002×7.5380/660/114014.8/8.7/5.0255~155380~35248622
№5.629002×7.5380/660/114014.8/8.7/5.0274~124354~35738622770×2100
29302×11380/660/114021.6/12.6/7.2345~191495~45188622
29302×15380/660/114028.8/17.0/9.6395~250700~47408622
№6.029302×15380/660/114028.8/17.0/9.6420~240350~51508622820×2500
29302×18.5380/660/114035.5/20.5/11.8486~256513~53308622
29402×22380/660/114041.0/24.4/13.67525~310615~54608622
№6.329302×15380/660/114028.8/17.0/9.6420~240350~51508622850×2500
29302×18.5380/660/114035.5/20.5/11.8486~256513~53308622
29402×22380/660/114041.0/24.4/13.67525~310615~54608622
29502×30380/660/114056.9/32.9/18.5590~320760~59008622850×2700
№7.129502×30380/660/114056.9/32.9/18.5620~370600~66248622930×2740
29502×37380/660/114067.9/40.3/22.6745~400890~66308622
29702×45380/660/114082.1/48.4/27.4830~5451450~67808622930×2830
№8.029502×30380/660/114056.9/32.9/18.5520~265400~660086221040×2760
29702×45380/660/114082.1/48.4/27.4680~380600~760086221040×2900
29702×55380/660/1140102.6/59.3/34.3820~480700~830086221040×3050
29702×75380/660/1140140.1/80.7/46.71260~6752160~717086221040×3190

Technical performance Parameters of Three Stages Ventilation Fan

TypeRotaltion RatePowerRated Voltage 

(V)

Single MotorCapacity M3/MinTotal Pressure PaMaximum Total Pressure

%

A Sound Level

(Db)

Outer Dimention
R/MinKwRated Current

(A)

Φ×L(Mm)
№4.028403×2.2380/6604.8/2.8226~110410~25908622575×2250
28803×3380/6606.4/3.7226~120410~26708622
28903×4380/6608.1/4.7226~146410~32908622
№5.029003×5.5380/660/114011.1/6.4/3.7245~155430~44308622700×2600
29003×7.5380/660/114014.8/8.7/5.0306~175470~50008622
№5.629303×11380/660/114021.6/12.6/7.2408~194500~60808622770×3560
29303×15380/660/114028.8/17.0/9.6460~245600~72408622
№6.329303×18.5380/660/114035.5/20.5/11.8510~245610~78508622850×3740
29403×22380/660/114041.0/24.4/13.67560~245610~85608622
29503×30380/660/114056.9/32.9/18.5640~252620~90008622
№7.129503×37380/660/114067.9/40.3/22.6745~4001170~91808622930×3830
29703×45380/660/114082.1/48.4/27.4830~5451450~92208622
№8.029703×55380/660/1140102.6/59.3/34.3990~6251810~933086221040×4250

Technical performance Parameters of Four Stages Ventilation Fan

TypeRotaltion RatePowerRated Voltage

 (V)

Single MotorCapacity M3/MinTotal Pressure PaMaximum Total Pressure

%

A Sound Level (Db)Outer Dimention
R/MinKwRated Current

(A)

Φ×L(Mm)
№4.028404×2.2380/6604.8/2.8226~110525~33308622575×2820
28804×3380/6606.4/3.7226~120525~39808622
№5.028904×4380/6608.1/4.7226~146525~42208622
29004×5.5380/660/114011.1/6.4/3.7245~155560~56908622700×3130
29004×7.5380/660/114014.8/8.7/5.0306~175590~64308622
№5.629304×11380/660/114021.6/12.6/7.2408~194610~73508622770×4180
29304×15380/660/114028.8/17.0/9.6460~245767~93808622
№6.329304×18.5380/660/114035.5/20.5/11.8510~245785~101008622850×4460
29404×22380/660/114041.0/24.4/13.67560~245785~110008622
29504×30380/660/114056.9/32.9/18.5640~252805~115708622
№7.129504×37380/660/114067.9/40.3/22.6745~4001450~118308622930×4570
29704×45380/660/114082.1/48.4/27.4830~5451810~118608622
№8.029704×55380/660/1140102.6/59.3/34.3990~6252160~1198086221040×5070